Technical data
No. of fiber | 4 | 8 | 12 | ||
Fiber Model | G.652D | ||||
Strength Member | Material | FRP | |||
Diameter(±0.05)mm | 1.5 | ||||
NO. | 2 | ||||
Loose Tube | Material | PBT | |||
Diameter(±0.06)mm | 2.8 | ||||
Thickness(±0.03)mm | 0.40 | ||||
Strength Member | Material | Glass Yarn | |||
Outer Sheath | Material | HDPE | |||
Color | Balck | ||||
Cable Diameter(±0.2)mm | 5.0×8.0 | ||||
Allowable Tensile Strength | 2000N | ||||
Allowable Crush Resistance | 1000N/100mm | ||||
Min. bending radius | Without Tension | 10.0×Cable-φ | |||
Under Maximum Tension | 20.0×Cable-φ | ||||
Temperature range (℃) | Installation | -20~+60 | |||
Transport&Storage | -40~+70 | ||||
Operation | -40~+70 |
Fibre Color
No. | 1 | 2 | 3 | 4 | 5 | 6 |
Color | Blue | Orange | Green | Brown | Gray | White |
No. | 7 | 8 | 9 | 10 | 11 | 12 |
Color | Red | Black | Yellow | Violet | Pink | Aqua |
Sheath marking
The optical fiber drop cable shall have sequentially numbered length marking at intervals of approximately 1 meter. The starting number of ordering length for any coil shall begin whit zero meter. The accuracy of the measurement of lenth marking shall be held within the limits of ±1%.
Manufacturer’s name
Type of wire
Year and month of manufacture
Length marking each meter along the wire